general-purpose-digital.png

m3000_angle1
Model 3000

 

  • Supports GM, Proportional & Scintillation Detectors
  • Optional Data Logging Capability

 

m3001_face_w_log-button--handle-1b
Model 3001

 

  • Supports GM, Proportional & Scintillation Detectors
  • Stores Up To 4 Detector Set-Ups
  • Optional Data Logging Capability

 

m3002_frontrtangleview_500
Model 3002

 

  • Supports Alpha-Beta Proportional & Scintillation Detectors
  • Includes Data Logging Capability

 

m30_face_133764959
Model 30

 

  • Attaches to Detector Allowing One-Handed Operation
  • Supports GM, Proportional & Scintillation Detectors

 

m35_angle

Model 3000

Digital Survey 

Part Number: 48-4035

Features

  • Large Backlit LCD for Ease of Reading
  • Auto Ranging
  • Rate, Max, and Count Modes of Operation
  • Splash-Resistant Construction for Outdoor Use
  • 4-Button Intuitive Interface for Easy Operation
  • All-Digital Calibration
  • USB Port
  • Lighter Weight yet Ruggedly Built

The Ludlum Model 3000 is a versatile, lightweight, ergonomically-designed instrument used with an external detector for alpha, beta, or gamma radiation survey. Three modes of operation – RATE, MAX, and COUNT – are available for the user. Measurements can be collected in two sets of units (primary and secondary) for RATE and MAX modes in cps, cpm, Bq, dpm, mR/hr, or µSv/h units. The user can switch between two sets of chosen units by simply pressing the Units button.

The standard handle includes the LOG pushbutton that allows the instrument to log up to 1000 data points when activated with the optional Lumic Datalogging Kit. See the Options tab for more information.

An internal switch is used to enable or disable the front-panel setup feature to protect desired settings from inadvertent modification. Setup is also available via software available from Ludlum Measurements. User-adjustable settings include calibration constant, dead time correction, efficiency, high voltage, pulse threshold, response time (fast or slow), count time, operational modes, HV current overload level, operational mode (Rate, Max, or Count), and minimum and maximum display levels. The user may also set Primary and Secondary units, unit alarm levels, count units, count alarm levels, and zero pulse protection time limit.

This instrument features a large, easily-readable LCD (liquid crystal display), an audio warning tone, and easy, intuitive, user-friendly design. Splash-resistant construction allows the Model 3000 to be used outdoors. The instrument body is made of lightweight, durable, high-impact plastic. The Model 3000 is shipped ready to use with batteries and calibration certificate.

The Model 3000 Series of Digital Survey Meter is available with several options that enable the user to further exploit the many features of this instrument. Several of these options are listed on the Options tab and on the Options Data Sheet found on the Documents tab.

 

Compatible Detectors GM, Proportional, Scintillation
LCD Display 3 digit LCD with large 20 mm (0.8 in.) digits, low-battery indicator, MAX, ALARM, AUDIO
Units: (k)cps, (k)cpm, (k)Bq, (k)dpm, (µ)(m)R(/h), (µ)(m)Sv(/h)
Display Range
  • 0.0 cps to 99.9 kcps
  • 0.00 cpm to 999 kcpm
  • 0.00 Bq to 99.9 kBq
  • 0.00 dpm to 999 kdpm
  • 0.00 µR/h to 999 R/h
  • 0.00 µSv/h to 999 Sv/h
Max Display can be set to limit display to calibrated range
Backlight Built-in ambient light sensor automatically activates low-power LED backlight, unless internal dipswitch is set to continuous-On (will reduce battery life)
Controls ON/OFF/ACK
  • Press to turn ON
  • Tap to acknowledge alarms and silence alarm tone
  • Press to reset Sigma Audio alarm
  • Hold for OFF
Mode Alternates between: 
  • NORMAL (count rate)
  • MAX (captures peak rate)
  • COUNT (user-selectable preset count time from 0 to 10 min)
Number of modes can be reduced in setup.
Audio
  • Turn “click” audio On/Off
  • Turn Sigma Audio beep On/Off
Units Changes the units between: 
  • Count rate (cpm, cps)
  • Dose/exposure (µSv/h, mR/h)
  • Disintegration (dpm, Bq)
Data Logging Handle Instrument is supplied with built-in push button data logging handle.
(NOTE: Datalogging Software [P/N 4498-1019] is required to use this feature)
Response Time User-selectable from 1 to 60 s, or Auto-Response Rate FAST or SLOW
Alarms Count rate, Exposure/Dose, and Scaler alarm setpoints adjustable over the display range
Overload High count rate saturation protection prevents false display of lower count rates
Zero Protection After a user-settable time interval (default 60 seconds) of no pulses from detector, unit will flash a zero reading and the alarm audio will be triggered
Dead Time Correction Employs first and second order corrections for extended performance
High Voltage 400 to 1500 Vdc
Audio < 75 dB at 0.6 (2 ft), approximately 4.5 kHz
Power Four alkaline or four rechargeable “AA” batteries (instrument does not support in-device charging)
Battery Life Approximately 750 hours of operation (as low as 100 hours with backlight configured for continuous-on), 16-hour low battery warning
Construction High-impact plastic with water-resistant rubber seals and separate battery compartment
Temperature Range -20 to 50 °C (-5 to 122 °F)
May be certified for operation from -40 to 65 °C (-40 to 150 °F)
Environmental Rating NEMA rating of 4x or IP rating of 53
Size (H x W x L) 16.5 x 11.4 x 21.6 cm (6.5 x 4.5 x 8.5 in.)
Weight 0.9 kg (2.0 lb)
Model 35

 

  • Vehicle Mounted Digital Survey Meter
  • Supports GM, Proportional & Scintillation Detectors